User Tools

Site Tools


testplaninv:30:use:editmark

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
testplaninv:30:use:editmark [2026/02/27 14:12]
admin [Command: Edit]
testplaninv:30:use:editmark [2026/03/02 15:15] (current)
admin [Characteristic Type: Simple Value]
Line 5: Line 5:
 Displays a dialog box in which the user can view and edit all characteristic values. The properties specific to the inspection characteristic are displayed in the Edit dialog box. There are properties that are the same for all characteristic types, such as the characteristic number or the data for the symbol and properties, which differ depending on the type of inspection characteristic indicated. Displays a dialog box in which the user can view and edit all characteristic values. The properties specific to the inspection characteristic are displayed in the Edit dialog box. There are properties that are the same for all characteristic types, such as the characteristic number or the data for the symbol and properties, which differ depending on the type of inspection characteristic indicated.
  
-{{:testplaninv:38:usage:screenshots:use_002_en.png?400|}}+{{:testplaninv:38:usage:screenshots:use_002_en.png?321|}}
  
 When an Inventor characteristic is marked, all required data is read from the Inventor characteristic and stored in a test plan characteristic. This allows the user to view and influence the data output later already during the marking process. Especially with chamfers as well as bore and thread labels, the characteristic data may only be read out very inaccurately from Inventor via the edit dialog, however, the user can now add the correct values directly. When an Inventor characteristic is marked, all required data is read from the Inventor characteristic and stored in a test plan characteristic. This allows the user to view and influence the data output later already during the marking process. Especially with chamfers as well as bore and thread labels, the characteristic data may only be read out very inaccurately from Inventor via the edit dialog, however, the user can now add the correct values directly.
Line 11: Line 11:
 \\  \\ 
 ===== Common Properties ===== ===== Common Properties =====
-{{:testplaninv:30:use:use_003_en.png?400|}}+{{:testplaninv:38:usage:screenshots:use_003_en.png?321|}}
  
 ^Name ^Description ^ ^Name ^Description ^
Line 25: Line 25:
 Also available in all dialogs are the following functions Also available in all dialogs are the following functions
  
-{{:testplaninv:30:use:use_004_en.png?400|}}+{{:testplaninv:38:usage:screenshots:use_004_en.png?321|}}
  
 ^Name ^Description ^ ^Name ^Description ^
Line 36: Line 36:
 The characteristic type "Dimension" has the following specific properties: The characteristic type "Dimension" has the following specific properties:
  
-{{:testplaninv:30:use:use_005_en.png?400|}}+{{:testplaninv:38:usage:screenshots:use_005_en.png?321|}}
  
 ^ Name ^ Description^ ^ Name ^ Description^
Line 54: Line 54:
 The characteristic type "Chamfer" has the following specific properties: The characteristic type "Chamfer" has the following specific properties:
  
-{{:testplaninv:30:use:use_007_en.png?400|}}+{{:testplaninv:38:usage:screenshots:use_007_en.png?401|}}
  
 ^ Name ^ Description ^ ^ Name ^ Description ^
Line 60: Line 60:
 |Angle  |Displays the angle determined from the Inventor feature. Detailed information on target value and tolerance: Can be entered in the subdialogue (button with arrow symbol). | |Angle  |Displays the angle determined from the Inventor feature. Detailed information on target value and tolerance: Can be entered in the subdialogue (button with arrow symbol). |
  
-<note>Two methods are available for reading out the Inventor characteristic data: Automatic mode and the pattern-based expert mode. Both procedures are described in the chapter [[testplaninv:30:administration|Administration]].</note>+<note>Two methods are available for reading out the Inventor characteristic data: Automatic mode and the pattern-based expert mode. Both procedures are described in the chapter [[testplaninv:38:administration|Administration]].</note>
  
 \\  \\ 
Line 67: Line 67:
 The characteristic type "Geometric Tolerance" has the following specific properties: The characteristic type "Geometric Tolerance" has the following specific properties:
  
-{{:testplaninv:30:use:use_008_en.png?400|}}+{{:testplaninv:38:usage:screenshots:use_008_en.png?401|}}
  
 ^ Name ^ Description ^ ^ Name ^ Description ^
Line 84: Line 84:
 The characteristic type "Surface Symbol" has the following specific properties: The characteristic type "Surface Symbol" has the following specific properties:
  
-{{:testplaninv:30:use:use_010_en.png?400|}}+{{:testplaninv:38:usage:screenshots:use_010_en.png?401|}}
  
 ^ Name ^ Description ^ ^ Name ^ Description ^
Line 100: Line 100:
 The characteristic type “Hole/Thread” has the following specific properties:  The characteristic type “Hole/Thread” has the following specific properties: 
  
-{{:testplaninv:30:use:use_012_en.png?400|}}+{{:testplaninv:38:usage:screenshots:use_012_en.png?400|}}
  
 ^ Name ^ Description ^ ^ Name ^ Description ^
Line 110: Line 110:
 |Values | Depending on the selected parameters, different target values are available. Detailed information on target value and tolerance can be entered in the subdialogue (button with arrow symbol). Predefined common target values can be loaded via the "Default values" property.| |Values | Depending on the selected parameters, different target values are available. Detailed information on target value and tolerance can be entered in the subdialogue (button with arrow symbol). Predefined common target values can be loaded via the "Default values" property.|
  
-<note>Two methods are available for reading out the Inventor characteristic data: Automatic mode and the pattern-based expert mode. Both methods are described in the chapter [[testplaninv:30:administration|Administration]].</note>+<note>Two methods are available for reading out the Inventor characteristic data: Automatic mode and the pattern-based expert mode. Both methods are described in the chapter [[testplaninv:38:administration|Administration]].</note>
  
 \\  \\ 
Line 117: Line 117:
 The characteristic type "Simple value" is a free inspection characteristic that is independent of Inventor and has the following specific properties: The characteristic type "Simple value" is a free inspection characteristic that is independent of Inventor and has the following specific properties:
  
-{{:testplaninv:30:use:use_014_en.png?400|}}+{{:testplaninv:38:usage:screenshots:use_014_en.png?401|}}
  
 ^ Name ^ Description ^ ^ Name ^ Description ^
Line 129: Line 129:
 The characteristic type "Text" is a free inspection characteristic that is independent of Inventor and has the following specific properties: The characteristic type "Text" is a free inspection characteristic that is independent of Inventor and has the following specific properties:
  
-{{:testplaninv:30:use:use_016_en.png?400|}}+{{:testplaninv:38:usage:screenshots:use_016_en.png?401|}}
  
 ^ Name ^ Description ^ ^ Name ^ Description ^
Line 138: Line 138:
  
 ---- ----
-The content refers to version 3.0+The content refers to version 3.8
testplaninv/30/use/editmark.1772197976.txt.gz · Last modified: 2026/02/27 14:12 by admin